Heating circuit calculator for BEKOTEC-THERM

Fast and easy calculation of the material requirements for your floor heating system from Schlüter-Systems!

A tradesman cuts a heating pipe to the length required for the heating circuit and lays it in an orange-coloured BEKOTEC studded panel from Schlüter-Systems.

Calculation of requirements made easy

Unsure about your planning? No problem: Our heating circuit calculator determines heating circuits, pipe requirements and volume flow for your BEKOTEC-THERM floor heating system in rooms from between 3 and 40 m2. Simply pick a studded panel, define the heating load or building type and enter the floor area – done!

Technical data

Estimated flow and return temperatures to achieve a room temperature of 20 °C

Covering Covering resistance Supply temperature Return temperature

Tile

0.00 m²k/W 35 °C 25 °C
Parquet up to 15 mm 0.10 m²k/W 45 °C 35 °C
Carpet 0.10 m²k/W 45 °C 35 °C
  • ∆θ 5K for room temperature 24 °C
  • Observe residual heat requirement, e.g. in bathrooms, WC rooms, conservatories
  • Pipe requirement incl. pipe connection to the distributor
  • Edge insulation strip ≈ room floor space x 1.2