Schlüter-DITRA-HEAT-E-DUO-S Complete sets with sound insulation for faster heat-up response
Conveniently order DITRA-HEAT-E as a complete set with all required system components for heated wall and floor areas.
Included in all sets:
- Schlüter-DITRA-HEAT-DUO-MA uncoupling mats
- Schlüter-DITRA-HEAT-E-HK heating cables
- 1 x Schlüter-DITRA-HEAT-E-R or Schlüter-DITRA-HEAT-E-R6 thermostat
- 2 x junction boxes
- 1 x conduit (3 m)
- Walls in interior spaces
- Floors in residential areas
- Sound insulation
- WiFi control
General product information
Function
What this product does
Schlüter-DITRA-HEAT-DUO is a polypropylene membrane with a cut-back stud structure and a special 2 mm anchoring fleece laminated on the underside. In addition to bonding with the tile adhesive, the material reduces impact sound and ensures a quicker heat up response.
It is a universal substrate for tile coverings that forms an uncoupling, crack bridging, waterproofing and vapour pressure equalisation layer and can also be used to attach heating cables.
The substrate for the installation of DITRA-HEAT-DUO must be level and load bearing. DITRA-HEAT-DUO is installed in thin-bed tile adhesive that is suitable for the substrate, using a notched trowel (recommended size: 6 x 6 mm). The anchoring fleece on the underside of DITRA-HEAT-DUO is fully embedded and the fabric bonds with the adhesive. The curing time of the adhesive must be observed.
In floor areas, the heating cables can be installed immediately after adhering DITRA-HEAT-DUO, using a minimum spacing of 9 cm (every third stud ≙ 136 W/m²).
For wall installation, the heating cables are installed once an adequate adhesive bond has been reached. The installation spacing is either 6 cm (every second stud ≙ 200 W/m²) or 9 cm (every third stud ≙ 136 W/m²). The use of mats is recommended for wall areas.
The tile or stone covering is installed directly over DITRA-HEAT-DUO in accordance with the applicable standards, using the thin-bed method. The thin-bed tile adhesive bonds with the cutback stud structure of the DITRA-HEAT-DUO membrane.
DITRA-HEAT-DUO is waterproof and resistant to any chemical stresses that typically occur in conjunction with tiled coverings. Where required, DITRA-HEAT-DUO can be used to create a certified bonded waterproofing assembly.
Use the cable tester Schlüter-DITRA-HEAT-E-CT to measure the resistance of the electrical heating cables DITRA-HEAT-E-HK and the remote sensors supplied with DITRA-HEAT-E thermostats. The testing device monitors the resistance of the heating cables during the entire installation phase and alerts the installer with an acoustic signal in the event of damage. The cable tester automatically shuts down 60 minutes after the last key activation (values will not be saved).
Summary of functions
a) Uncoupling
Schlüter-DITRA-HEAT-DUO uncouples the covering from the substrate and neutralises stresses between the substrate and the tile or stone covering that result from various deformations. It also bridges tension cracks from the substrate and prevent them from affecting the tile covering.
b) Waterproofing
Schlüter-DITRA-HEAT-DUO is a waterproof polypropylene membrane with a relatively high water vapour diffusion seal. With properly installed abutting joints and carefully sealed transitions to walls and structural elements, DITRA-HEAT-DUO can be used to create a certified bonded waterproofing assembly with the tile covering.
DITRA-HEAT-DUO can be installed in accordance with the waterproofing standard DIN 18534 applicable in Germany. Water exposure classes: W0-I to W3-I. DITRA-HEAT-DUO also features the national technical approval (abP) required in Germany.
Moisture load class according to ZDB: 0 to B0, as well as A.
DITRA-HEAT-DUO has a European Technical Assessment (ETA) pursuant to ETAG 022 (watertight covering kits) and bears a CE mark.
System-certified tile adhesives must be used in areas that require CE-compliance or assemblies according to abP (certificate of technical approval). Please contact us using the details listed at the bottom of this page for further information about such tile adhesive products and the corresponding certificates of technical approval.
DITRA-HEAT-DUO effectively protects the sub-structure from damage caused by permeating moisture or aggressive substances.
c) Load distribution (load induction)
Tiles installed over Schlüter-DITRA-HEAT-DUO in floor areas should have a minimum size of 5 x 5 cm and a thickness of at least 5.5 mm. The adhesive-filled, square recesses of DITRA-HEAT-DUO transfer mechanical stresses impacting the tile covering directly to the substrate. This makes tile coverings installed on DITRA-HEAT-DUO especially durable. The tiles for the corresponding application area must be sufficiently thick and have adequate compressive stability to withstand high traffic loads (e.g. in commercial areas) or large point loads (such as concert pianos, forklifts, or shelf systems). In Germany, the guidelines of the ZDB information sheet “Ceramic floor coverings for high mechanical impact” must be observed for tile thicknesses.
Tiles in high-stress areas must be fully embedded in the tile adhesive.
DITRA-HEAT-DUO, with its special 2 mm anchoring fleece laminated on the underside, is suitable for traffic loads of up to 3 kN/m². This includes residential and commercial premises with light foot traffic (private homes, office and administrative spaces, restaurants, hotels, conference rooms, nursing stations and patient rooms etc.).
The impact of hard objects must be avoided on ceramic coverings installed over DITRA-HEAT-DUO. The tile dimensions should be at least 5 x 5 cm.
d) Bonded assembly
Based on the fleece fabric bond in the thin-set adhesive on the substrate, and through mechanical anchoring of the thin-set adhesive in the cut-back stud structure, Schlüter-DITRA-HEAT-DUO creates a strong bond between the tile assembly and the substrate. That makes DITRA-HEAT-DUO suitable for both wall and floor installation.
e) Thermal separation
Schlüter-DITRA-HEAT-DUO has a special 2 mm anchoring fleece laminated on the underside. In addition to bonding with the tile adhesive, the material reduces impact sound and ensures a quicker heat-up response.
f) Sound insulation
An impact sound improvement value (ΔLW) of 13 dB was measured (according to DIN EN ISO 10140) in fully installed Schlüter-DITRA-HEAT-DUO assemblies.
The actual improvement offered by the respective assembly depends on the local conditions (structural design) and can deviate from this value. The measured test values therefore don't apply equally to every building situation.
Installation
How to install this product
The electrical installation must be performed by a qualified electrician (EN 60335-1). The heating cables must feature a multi pole circuit breaker with a contact clearance of at least 3 mm per pole. To protect against inadvertent contact, an RCD (FI circuit breaker) with a tripping current of IΔN ≤ 30 mA must be installed.
Further information on installing the heating cables and installing and setting up the thermostat can be found in the respective installation instructions.
Positioning the floor sensor
Variant A: The floor sensors are positioned directly in the newly installed uncoupling mat Schlüter-DITRA-HEAT-DUO. Since the floor sensor is embedded directly in the thin-bed tile adhesive and cannot be replaced, the installation must include a spare sensor (a second sensor is included in thermostat scope of supply as a spare sensor). Place the sensors in the centre between two heating cable loops.
Variant B: Position the floor sensor of the thermostat in the conduit with the sensor sleeve directly in the floor below the DITRA-HEAT-DUO uncoupling mat. Cut an opening in the heating mat DITRA-HEAT-DUO in the area of the sensor sleeve. Insert the sensor into the conduit and slide the sleeve over it (conduit and sensor sleeve are available as an installation set, Art.-No. DH EZ S1).
To guarantee an optimal temperature transition from the heated area to the sensor, no insulation material may be located between the sensor sleeve and DITRA-HEAT-DUO. In this case, cut an opening in the insulation in the area of the sensor sleeve.
Note: Before embedding the sensors with thin-bed tile adhesive, measure the resistance values, e.g. with the cable tester DITRA-HEAT-E-CT, and compare them with the values listed in the thermostat installation instructions.
- The substrate must be level, load-bearing and free of components that may inhibit bonding. Any necessary levelling work must be completed before installing DITRA-HEAT-DUO.
- The selection of the adhesive for installing DITRA-HEAT-DUO depends on the substrate.
The adhesive must bond with the substrate and mechanically set in the DITRA-HEAT-DUO anchoring fleece. A dry setting thin-bed tile adhesive is suitable for most substrates. The adhesive should preferably have a consistency suitable for fluid beds. Review any potential material incompatibilities beforehand. If using covering materials with a side length exceeding 30 cm, we recommend a quick-setting tile adhesive with crystalline water binding capacity for fast curing and drying of the mortar.
- Apply a suitable thin-bed tile adhesive on the substrate with a notched trowel (6 x 6 mm). To achieve better initial adhesion for installation in wall areas, we recommend applying a contact layer on the reverse side of DITRA-HEAT-DUO.
- Embed the DITRA-HEAT-DUO mats, which must have been cut to size beforehand, into the installed adhesive with the anchoring fleece facing down. Immediately press them in place with a float or roller, working in a single direction. The curing time of the adhesive must be observed. For efficient installation of product rolls, precisely align DITRA-HEAT-DUO and keep the material stretched with light tension when placing it on the substrate.
The EasyCut gridlines minimise the curling memory. Mats are recommended for wall applications for easier handling. The mats or membranes are installed with closely abutting joints.
- To prevent any damage to the installed DITRA-HEAT-DUO material or detachment from the substrate, protect the area from mechanical stresses, e.g. by setting out running boards (particularly in the centre areas used for material transport).
Heating cable installation
- For installation in floor areas, heating cables may be installed immediately after adhering the uncoupling mat DITRA-HEAT-DUO, using a float or roller.
For wall installation, the heating cables are installed once an adequate adhesive bond has been reached.
Heating cables must never overlap or touch each other. - Create a corresponding indentation in the area of the sealed cable end.
Note: Use the cable tester Schlüter-DITRA-HEAT-E-CT to continuously measure the resistance of the electrical heating cables DITRA-HEAT-E-HK. The device monitors the resistance of the heating cables during the entire installation phase and alerts the installer with an acoustic signal in the event of damage.
- For installation in floor areas, heating cables may be installed immediately after adhering the uncoupling mat DITRA-HEAT-DUO, using a float or roller.
- Floor areas:
The stud spacing in the uncoupling mat is 3 cm. The installation spacing in the floor area must be
- at least 9 cm (around every third stud – the equivalent of 136 W/m²)
Closer installation spacing - especially in floor areas - may lead to overheating and can cause damage to building structures.
Avoid stepping directly onto heating cables during the installation work.
- Wall areas:
Depending on the available space, the desired surface temperature and the required heat output, the installation spacing in wall areas can either be
- 6 cm (around every second stud – the equivalent of 200 W/m²) or
- 9 cm (around every third stud – the equivalent of 136 W/m²)
- The transition from the heating cable to the connection cable (sleeve) is marked with an imprint as shown. The sleeve also has a sticker on that reads "Connection". The connection cable is labelled with the imprinted marking "COLD" further on. This 'cold leg' (4 m) must be connected directly to a junction box or thermostat. The 'cold leg' may be shortened to a max. length of 1 m before the fitting. The heating cables may not be shortened.
- After installing and checking the heating cables as specified in the installation instructions for DITRA-HEAT-E, the tiles can be installed in the thin-set method, using a thin-bed tile adhesive that meets the requirements of the respective covering. For maximum efficiency, fill the indentations of the heating mat with the smooth side of a notched trowel (heating cable and fittings must be completely embedded within the tile adhesive) and groove the thin-bed tile adhesive with the notched side of the trowel to prepare for tile installation. The notch size of the trowel must match the tile size to completely embed the tiles in the thin-bed tile adhesive. Observe the curing time of the adhesive.
- Follow the instructions in the data sheet to install movement joints for perimeter, edge and transition profiles.
Note: The thin-bed tile adhesive and the covering material used in conjunction with DITRA-HEAT-DUO must be suitable for the respective application area and meet the corresponding requirements. Wait at least 7 days after completing the covering assembly to heat up the DITRA-HEAT-E system for the first time.
Note for installing DITRA-HEAT-DUO in wall areas:
To mark the heated wall space (and avoid inadvertent drilling into a heating cable), we recommend using Schlüter profiles (such as RONDEC, QUADEC or DESIGNLINE) to visually outline the corresponding area.
In the case of heated wall areas exceeding a length of 3 m, the wall and connection joints must have a permanently elastic design to accommodate thermal expansion.
Waterproofing with Schlüter-DITRA-HEAT-DUO
DITRA-HEAT-DUO can be used to create certified waterproofing assemblies with tile coverings, provided the abutting membrane joints and the connections to installed components and upright building structures are carefully sealed.
DITRA-HEAT-DUO also features the national technical approval (abP) required in Germany and has an Ü-mark quality seal for construction products. Moisture load class according to abP: 0 - B0 and A.
DITRA-HEAT-DUO has a European Technical Assessment (ETA) pursuant to ETAG 022 (watertight covering kits) and bears a CE mark.
Moisture load class according to ETAG 022: A.
System-certified tile adhesives must be used in areas that require CE-compliance or assemblies according to abP (certificate of technical approval).
Please contact us using the details listed at the bottom of this page for further information about such tile adhesive products and the corresponding certificates of technical approval.
DITRA-HEAT-DUO protects the substrate from damage caused by permeating moisture and aggressive substances. For seam sealing, trowel the sealing adhesive Schlüter-KERDI-COLL-L over the abutting joints and fully embed Schlüter-KERDI-KEBA in a minimum width of 12.5 cm over the seam.
To waterproof floor-wall transitions, adhere KERDI-KEBA over DITRA-HEAT-DUO on the floor and directly on the substrate in wall areas in the corresponding width. The sealing band must have a coverage of at least 5 cm. KERDI-KEBA can also be used to create functional connections to fixed structural components such as door and window frames made of metal, wood or plastic. The first step is to apply Schlüter-KERDI-FIX to the adhesive surfaces of the structural elements. The remaining width is then adhered to DITRA-HEAT with KERDI-COLL-L.
The suitability of KERDI-FIX for the respective materials of the structural elements must be verified in advance. Separate DITRA-HEAT-DUO at existing movement joints or expansion joints and seal the abutting joints with Schlüter-KERDI-FLEX. Never run heating cables over expansion joints or dummy joints.
KERDI-FLEX should also be used for flexible finishing edges. As an alternative, this can also be done with a sufficient loop of KERDI-KEBA.
Note on floor drains:
Schlüter-KERDI-DRAIN and Schlüter-KERDI-LINE are a special drainage system designed for connection to bonded waterproofing assemblies. Schlüter-DITRA-HEAT-DUO can easily and quickly be combined with these components by using pre-fabricated KERDI collars.
Thermostat:
The heating cables of the DITRA-HEAT-DUO system may only be operated with DITRA-HEAT-E thermostats.
Substrates for Schlüter-DITRA-HEAT-DUO
Always check that the substrates on which DITRA-HEAT-DUO is to be installed are level, load bearing, clean and compatible with the materials to be used. Remove all surface components that may weaken the bond. Any levelling, height adjustment or slope compensation must be carried out before installing DITRA-HEAT-DUO.
To guarantee effective floor heating, thermal insulation is required, especially for installations adjoining soil or unheated spaces.
For a faster heat-up response on unheated screed assemblies, we recommend using DITRA-HEAT-DUO for its thermal separation function or Schlüter-KERDI-BOARD as an insulation layer (see data sheet 12.1).
Concrete
Concrete undergoes long-term structural deformation due to shrinkage. In addition, tension can build up in concrete and pre-stressed concrete due to deflection.
Since DITRA-HEAT-DUO absorbs the resulting stresses between the concrete and the tile covering, tiles can be immediately installed as soon as the concrete is ready to bear weight.
Cement screeds
In accordance with the applicable regulations, cement screeds must have cured for a minimum of 28 days prior to tile installation and have a moisture content below 2 CM %.
Floating and heated screeds have a particular tendency to buckle and crack even later, e.g. due to mechanical stresses and temperature fluctuations. With DITRA-HEAT-DUO, tiles can be installed on green cement screeds as soon as they are ready to bear weight.
DITRA-HEAT-DUO will neutralise cracks and screed deformations developing later and will prevent them from affecting the tile covering.
Gypsum based screeds
According to the applicable rules, gypsum based (anhydrite) screed may not have a residual moisture level of more than 0.5 CM % at the time of tile installation. In contrast, tile installation is permissible from a residual moisture level of 2 CM % with DITRA-HEAT-DUO.
If necessary, the screed surface must be treated (grinding, priming) as specified by the applicable technical regulations and manufacturer instructions. DITRA-HEAT-DUO can be installed with suitable thin-bed tile adhesives. DITRA-HEAT-DUO protects the screed surface against permeating moisture. Because gypsum based screeds are susceptible to moisture, screeds must be protected against humidity, e.g. moisture seepage on the underside.
Heated screeds
Note: Due to the thermal separation properties of the product, DITRA-HEAT-DUO should not be installed over heated screeds.
Vinyl coverings and coatings
All surfaces must be load bearing and pre-treated or suitable for bonding with an appropriate adhesive, in which the DITRA-HEAT-DUO anchoring fleece can be embedded. The compatibility of the adhesive with the substrate and with DITRA-HEAT-DUO must be verified in advance.
Chipboard and compressed wood panels
These materials undergo significant deformation based on the influence of moisture (or fluctuations in humidity). It is therefore recommended to use chipboard and compressed wood panels with special water-repellent treatment to protect against moisture.
Such panels can generally be used as a floor and wall substrate in interior spaces. Refer to local regulations if these are acceptable. However, they have to be thick enough to be sufficiently stable in conjunction with a suitable support assembly.
The structure should be fastened with closely spaced screws. Abutments must have a tongue and groove connection and be fully sealed. Perimeter movement joints of about 10 mm have to be maintained at the transition to upright building structures. DITRA-HEAT-DUO neutralises any tensions with the tile covering and also prevents permeating moisture.
Hardwood floors
In principle, ceramic coverings can be installed on sufficiently weight bearing hardwood floors with tongue and groove connections. The wooden substrate should have balanced moisture levels before DITRA-HEAT-DUO can be installed. It has proven beneficial to install an additional layer of chipboard or compressed wood panels. Uneven floor surfaces should be levelled with suitable measures beforehand.
Masonry / mixed substrates
Masonry structures built with bricks, sand lime bricks, cement blocks, aerated concrete or similar materials are generally a suitable substrate for DITRA-HEAT-DUO. The substrate must be levelled in advance. In restoration and refurbishment projects, substrates frequently consist of different materials (mixed masonry), which have a tendency to crack at the interfaces with other materials due to different deformation rates. DITRA-HEAT-DUO protects the tile covering from the resulting stresses and cracks.
Gypsum plaster / bricks
Gypsum substrates should be completely dry in accordance with the relevant regulations. The surfaces may need to be pre-treated with a primer. DITRA-HEAT-DUO can be installed with dry-setting or other suitable thin-bed tile adhesives.
Material
What this product is made from
Schlüter-DITRA-HEAT-DUO is a polypropylene membrane with a cut back stud structure and imprinted EasyCut gridlines. A fleece fabric is laminated on the underside. The product thickness, including the stud structure, is approx. 7.5 mm.
Polypropylene is not UV-stable in the long term; the product should not be stored in places with prolonged exposure to direct sunlight.
Material properties and areas of application
Schlüter-DITRA-HEAT-DUO is non-rotting, waterproof, stretchable and crack-bridging. In addition, it is largely resistant to the effects of aqueous solutions, salts, acids and alkalis, many organic solvents, alcohols and oils.
Product resistance to special local conditions must be verified separately based on the anticipated concentration, temperature and length of exposure. The product has a relatively high water vapour diffusion seal. The material is non toxic and physiologically harmless.
Product suitability must be verified in applications exposed to chemical or mechanical stresses. The information provided on this page is intended as a general guideline.
Depending on the system, stepping on coverings installed over DITRA-HEAT-DUO with hard shoes or tapping them with a hard object may produce a hollow sound.
The use of DITRA-HEAT-DUO in conjunction with heating cables as a floor/wall heating system is only permitted for interior areas.
Maintenance & Care
How to look after this product
The thin-bed tile adhesive and the covering material used in conjunction with Schlüter-DITRA-HEAT-DUO must be suitable for the respective application area and meet the corresponding requirements.
If the covering materials to be installed are sensitive to moisture (e.g. natural stone or agglomerate stone pavers) or if moisture is present on the underside (e.g. from green screeds), the abutting seams of DITRA-HEAT-DUO mats should be fully covered with the sealing adhesive Schlüter-KERDI-COLL-L, and completely covered with the sealing tape Schlüter-KERDI-KEBA in a minimum width of 12.5 cm.
The use of quick-curing cementitious tile adhesives may be an advantage for certain projects. It is recommended to set out running boards to protect DITRA-HEAT-DUO from mechanical stresses caused by material transport.
Notes on movement joints
Separate the Schlüter-DITRA-HEAT-DUO membrane over existing movement joints. Never run heating cables over movement joints. Continue the movement joints in the tile covering as specified by the applicable standards. Otherwise, divide large coverings installed over DITRA-HEAT-DUO into sections, using movement joints according to the applicable regulations.
We recommend using the profiles of the Schlüter-DILEX family. Arrange profiles such as Schlüter-DILEX-BT or Schlüter-DILEX-KSBT over existing expansion joints depending on the anticipated structural movements.
It is important to prevent stress build-up at the edges of the covering, for instance at upright structural components or at floor-wall transitions. Perimeter movement joints and connection joints must be constructed according to the applicable technical regulations and have sufficient dimensions to prevent stress build-up. We recommend using the various profile types of the DILEX family.