Schlüter-DITRA-HEAT-E-HK  Electrical heating cable for the DITRA-HEAT-E system

The electrical heating cable Schlüter-DITRA-HEAT-E-HK is installed in the uncoupling mat Schlüter-DITRA-HEAT and is used for applications in floor and wall assemblies. It is available in lengths from 4 to 244 metres. Since our systems are certified for waterproofing, the heating cables are approved for use in bathrooms and wetrooms.

Note: Heating cables must not be shortened.
When selecting the heating cable, please note that the product table indicates the heated space in m², not the room size. To determine the heated space, deduct unheated zones such as perimeter areas and storage space from the room size.


Product image DITRA-HEAT-E-HK 1©Schlüter-Systems KG
Product image DITRA-HEAT-E-HK 2©Schlüter-Systems KG
Product image DITRA-HEAT-E-HK 3©Schlüter-Systems KG
zoom_out_map search
Product image DITRA-HEAT-E-HK 1
Product image DITRA-HEAT-E-HK 2
Product image DITRA-HEAT-E-HK 3

General product information

What this product does

In floor areas, the heating cables can be installed immediately after adhering DITRA-HEAT, using a minimum spacing of 9 cm (every third stud ≙ 136 W/m²).

For wall installation, the heating cables are installed once an adequate adhesive bond has been reached. The installation spacing is either 6 cm (around every second stud ≙ 200 W/m²) or 9 cm (every third stud ≙ 136 W/m²). The use of mats is recommended for wall assemblies.

Use the cable tester Schlüter-DITRA-HEAT-E-CT to measure the resistance of the electrical heating cables DITRA-HEAT-E-HK and the remote sensors supplied with DITRA-HEAT-E thermostats. The testing device should be used to monitor the resistance of the heating cables during the entire installation phase and alerts the installer with an acoustic signal in the event of damage. The cable tester automatically shuts down 60 minutes after the last key activation (values will not be saved).

How to install this product

The electrical installation must be performed by a qualified electrician in accordance with BS7671. The heating cables must feature a multi pole circuit breaker with a contact clearance of at least 3 mm per pole. To protect against inadvertent contact, an RCD (FI circuit breaker) with a tripping current of IΔN ≤ 30 mA must be installed.

Further information on installing the heating cables and installing and setting up the thermostat can be found in the respective installation instructions.

Heating cable installation

    1. For installation in floor areas, heating cables may be installed immediately after adhering the uncoupling mat DITRA-HEAT, using a float or roller.
      For wall installation, the heating cables are installed once an adequate adhesive bond has been reached.
      Heating cables must never overlap or touch each other.
    2. Create a corresponding indentation in the area of the sealed cable end.
      Note: Use the cable tester Schlüter-DITRA-HEAT-E-CT to continuously measure the resistance of the electrical heating cables DITRA-HEAT-E-HK. The device monitors the resistance of the heating cables during the entire installation phase and alerts the installer with an acoustic signal in the event of damage.
  1. Floor areas:
    The stud spacing in the uncoupling mat is 3 cm. The installation spacing in the floor area must be
  • at least 9 cm (around every third stud – the equivalent of 136 W/m²)
    Closer installation spacing - especially in floor areas - may lead to overheating and can cause damage to building structures.
    Avoid stepping directly onto heating cables during the installation work.
  1. Wall areas:
    Depending on the available space, the desired surface temperature and the required heat output, the installation spacing in wall areas can either be
  • 6 cm (around every second stud – the equivalent of 200 W/m²) or
  • 9 cm (around every third stud – the equivalent of 136 W/m²)
  1. The transition from the heating cable to the connection cable (sleeve) is indicated with a label. The 'cold leg' (4 m) must be connected directly to a junction box or thermostat. The 'cold leg' may be shortened to a max. length of 1 m before the fitting. The heating cables may not be shortened.

Thermostat:

The heating cables of the DITRA-HEAT system may only be operated with DITRA-HEAT-E thermostats.

What this product is made from

Material properties and areas of application

The use of DITRA-HEAT in conjunction with heating cables as a floor/wall heating system is only permitted for interior areas.